This is the new JJ-CCR CE-Edition, launched in August 2014. Equipped with a Petrel computer, a digital HUD, manual supplemental O2 and diluent valves with the option of feeding in external gases. The rebreather comes ready to fly right out of the box. Fill it with gas and sofnolime and serious adventures is just about to begin. The philosophy behind the JJ-CCR is to keep it simple; K.I.S.S. simple… The JJ-CCR has a robust construction with minimalistic detail work. It gives the diver a versatile rebreather, still very easy to handle as well as to deal with before and after operations. It is a rebreather built by divers and diving engineers. All components has a purpose and every detail can be justified in order to perform as a system helping the diver to reach his goals. The JJ-CCR is equipped with state of the art electronics and computing but it will still demand a skilled diver fully aware of the Pro´s and Con´s of technical rebreathers.
The JJ-CCR is an extremely versatile rebreather which is helping JJ-CCR divers to reach fantastic places.
Technical Information
Dimensions | 70cm x 40cm x 26cm including the handle | ||||||||||||||||||||||||||||||||||
Weight | 34.2kg – Ready for operation with 2 x 3 litre tanks19,8kg – Without tanks and soda lime | ||||||||||||||||||||||||||||||||||
Soda lime canister |
|
||||||||||||||||||||||||||||||||||
Soda lime | The only supported soda lime is: Sofnolime® 797 manufactured by Molecular Products. |
||||||||||||||||||||||||||||||||||
Oxygen Cylinder | 3 Liter steel cylinder (200 bar) | ||||||||||||||||||||||||||||||||||
Diluent Cylinder | 3 Liter steel cylinder (200 bar) | ||||||||||||||||||||||||||||||||||
On board gas duration | Oxygen: The on board oxygen supply will last 252 minutes, if the diver consumes1.78 liter of oxygen per minute.3 liter x 200 bar = 600 liter – 25% reserve = 450 literDiluent: The duration depends on the depth and activity of the diver.3 liter x 200 bar = 600 liter | ||||||||||||||||||||||||||||||||||
Batteries | 2 x 3.6v lithium (SAFT 14500). One battery for the controller and one battery for the HUD.2 x 9v block lithium (Parallel operation for the solenoid) |
||||||||||||||||||||||||||||||||||
Volume of the counter lungs | 8 litres | ||||||||||||||||||||||||||||||||||
Maximum application depth | Max. 40 m with air as diluent Max. 100 m with trimix as diluentWarning: Dives exceeding a depth of 100 m are associated with numerous additional risks |
||||||||||||||||||||||||||||||||||
Purity of the gases |
|
||||||||||||||||||||||||||||||||||
Atmospheric pressure range | 800 – 1050mbar | ||||||||||||||||||||||||||||||||||
1st stage “oxygen” | Connection: M26x2 – medium pressure: 7.0 to 7.5 bar | ||||||||||||||||||||||||||||||||||
1st stage “diluent” | Connection: DIN 5/8″- medium pressure: 9.0 to 10.0 bar | ||||||||||||||||||||||||||||||||||
Oxygen control | Two oxygen setpoints (low and high). Can be switched as many times as required, also changeable under water. |
||||||||||||||||||||||||||||||||||
Oxygen setpoint range | From 0.4 to 1.5 bar (low and high) | ||||||||||||||||||||||||||||||||||
Oxygen warnings |
|
||||||||||||||||||||||||||||||||||
Oxygen sensors | 3 galvanic cells (type: R17JJ-CCR) | ||||||||||||||||||||||||||||||||||
Operating temperatures |
|
||||||||||||||||||||||||||||||||||
Need More Information?
For more information on JJ Rebreathers or conducting a JJ-CCR course with Tekdeep Egypt please do not hesitate to contact us